Call Us: +8615989235884Email: zhangjianfeng13@jianhuaintl.com
enLanguage
Export North America ACSR Overhead Wire Aluminum Area 240mm2 Steel Area 40mm2 ACSR Overhead Power Lines

Export North America ACSR Overhead Wire Aluminum Area 240mm2 Steel Area 40mm2 ACSR Overhead Power Lines

Used for mechanical re-inforcement in the manufacture of aluminum conductor steel reinforced(ACSR) Cable & Conductor ACSR Core wire is used in reinforcement of aluminium conductors used in distribution and transmission of electricity.

Since the development of our company, we have a set of large-scale marketing system, and our Prestressed steel strand ASTM A416, Concrete Cone Electric Pole Manufacturing Equipment, GL coils in sheets anti finger are distributed in many international markets. We have a keen eye, flexible thinking, and immediate response to problems. We believe that in the fierce industry competition in the future, we will become an indispensable help for the industry.

Product Introduction

High Strength Galvanized Steel Strand is a steel strand with national standard quality, high tensile strength and long service life. It can be used in the construction of agricultural greenhouses, power communications and transportation. It is convenient and fast, can be bent and laid according to the construction environment and terrain, and has high flexibility. It is suitable for a variety of scenarios, has a wide range of uses, and has strong applicability.

Features

High Strength Galvanized Steel Strand uses advanced galvanizing technology. It has great anti-corrosion, anti-rust and corrosion resistance. It has strong bearing capacity and good toughness . It has complete specifications for you to choose according to your needs. It is not easy to rust. It is a product with high quality, good functionality,  and please rest assured to use.

Wire Dia.: 1x7 4.2mm-12.0mm; 1x19 8.0mm-17.5mm

1) Application: Used for mechanical re-inforcement in the manufacture of aluminum conductor steel reinforced(ACSR) Cable & Conductor ACSR Core wire is used in reinforcement of aluminium conductors used in distribution and transmission of electricity. ACSR Core strand.

2) Material: high carbon steel, High strength Galvanized Steel Strand

3) Construction: 3-wire strand (1×3), 7-wire strand (1×7), 19-wire strand (1×19), 37-wire strand (1×37)

Strand sizes: 1.0mm — 18.92 mm

4) Tensile strength: different Grade from min.1470 N/mm² to min.1960N/mm²

20210705094301df6b24571dcb4d46aa844b2e483d3be6

20210705094308297035d0e1ef4d37b8af15ba4e03c7df

The size of Galvanized Steel Strand for ACSR as follows

m㎡ Nominal Cross-section area

Construction Number of Wires

m㎡ Calculated Cross-section area

mm Diameter

Kg/km

Weight per length

KN

Minimum breaking load of strand

20 Ω/km

20 centigrade DC Resistance

Wire Dia.

Strand Dia.

JG1A

JG2A

JG3A

JG4A

JG5A

10

7

10.8

1.40

4.20

84.8

14.44

15.62

17.46

20.15

21.12

17.9754

15

7

17.8

1.80

5.40

140.1

23.87

25.83

28.86

33.31

34.91

10.8740

20

7

22.0

2.00

6.00

173.0

29.47

31.89

35.63

41..12

43.10

8.8079

25

7

26.6

2.20

6.60

209.3

35.66

38.58

43.11

49.76

52.15

7.2793

35

7

37.2

2.60

7.80

292.4

48.69

52.40

59.09

67.64

70.99

5.2118

50

7

49.5

3.00

9.00

389.2

64.82

69.77

78.67

90.05

94.51

3.9146

55

7

56.3

3.20

9.60

442.9

72.62

79.38

87.26

99.65

105.3

3.4406

65

7

67.3

3.50

10.5

529.8

86.88

94.96

104.4

119.2

125.9

2.8761

80

7

79.4

3.80

11.4

624.5

102.4

109.6

120.7

136.5

144.5

2.4399

90

7

88.0

4.00

12.0

692.0

113.5

121.4

133.7

151.3

160.1

2.2020

m㎡ Nominal Cross-section area

Construction Number of Wires

m㎡ Calculated Cross-section area

mm Diameter

Kg/km Weight per length

KN Minimum breaking load of strand

Ω/km

20 centigrade DC Resistance

Wire Dia.

Strand Dia.

JG1A

JG2A

JG3A

JG4A

JG5A

40

19

38.2

1.60

8.00

301.9

51.19

55.39

61.89

71.44

74.88

5.0939

50

19

48.3

1.80

9.00

382.1

64.79

70.11

78.33

90.41

94.76

4.0248

60

19

59.7

2.00

10.0

471.7

79.98

86.55

96.70

111.6

117.0

3.2601

70

19

72.2

2.20

11. 0

570.8

96.78

104.73

117.00

135.1

141.6

2.6943

80

19

78.9

2.30

11.5

623.9

103.4

111.3

125.5

143.7

150.8

2.4651

95

19

94.8

2.52

12.6

748.9

124.14

133.62

150.68

172.5

181.0

2.0535

100

19

101

2.60

13.0

797.2

132.1

142.2

160.4

183.6

192.7

1.9291

125

19

125

2.90

14.5

991.8

164.4

177.0

199.5

228.4

239.7

1.5506

150

19

153

3.20

16.0

1207.6

197.1

215.5

236.9

270.5

285.7

1.2735

185

19

183

3.50

17.5

1444.7

235.8

257.8

283.3

323.6

341.8

1.0645

YB/T5004 According to YB/T5004

dmm Nominal wire dia.

Nominal tensile strength Mpa

L0=200mm Elongation in 200mm min, %

Twist(No./360°)(L0=100d) Nominal tensile strength/Mpa

1270

1370

1470

1570

1670


Not less than

1.40

1270

1370

1470

1570

1670

2.0

18

16

16

14

12

1.50

1.60

1.70

1.80

3.0

16

14

14

12

10

2.00

2.20

2.40

3.0

16

14

14

12

10

2.60

2.80

14

12

12

10

8

3.00

3.5

14

12

12

10

8

3.20

3.50

3.80

4.00

Dominal Dia And Breaking Load

Construction

mm Wire dia.

mm Nominal strand dia.

m㎡ Nominal Cross-section area

Nominal tensile strength Mpa

Weight kg per km

1270

1370

1470

1570

1670

Minimum breaking load of strand

1x7

1.40

4.20

10.78

12.60

13.59

14.58

15.57

16.56

85.60

1.60

4.80

14.07

16.44

17.73

19.03

20.32

21.62

112.00

1.80

5.40

17.81

20.81

22.45

24.09

25.72

27.36

141.00

2.00

6.00

21.99

25.69

27.72

29.74

31.76

33.79

175.00

2.20

6.60

26.61

31.10

33.55

36.00

38.45

40.88

210.00

2.60

7.80

37.17

43.43

46.85

50.27

53.69

57.11

295.00

3.00

9.00

49.50

57.86

62.42

66.98

71.54

76.05

411.90

3.20

9.60

56.30

65.78

70.96

76.14

81.32

86.50

447.00

3.50

10.50

67.35

78.69

84.89

91.08

97.28

103.48

535.00

3.80

11.40

79.39

92.76

100.10

107.40

114.70

121.97

630.00

4.00

12.00

87.96

102.8

110.90

119.00

127.00

135.14

698.00

1X19

1.60

8.00

38.20

43.66

47.10

50.54

53.98

57.41

304.00

1.80

9.00

48.35

55.26

59.62

63.97

68.32

72.67

385.00

2.00

10.00

59.69

68.23

73.60

78.97

84.34

89.71

475.00

2.20

11.00

72.20

82.58

89.00

95.58

102.09

108.52

569.00

2.30

11.50

78.94

90.23

97.33

104.40

111.50

118.65

628.00

2.60

13.00

100.90

115.30

124.40

133.50

142.60

151.65

803.00

2.90

14.50

125.50

143.40

154.70

166.00

177.30

188.63

999.00

3.20

16.00

152.80

174.70

188.40

202.20

215.90

229.66

1220.00

3.50

17.50

182.80

208.90

225.40

241.80

258.30

274.75

1460.00

4.00

20.00

238.80

272.90

294.40

315.90

337.40

358.92

1900.00

Zinc Coating Requirement

d mm Nominal wire dia.

Zinc-coated weight g/㎡

Class A

1.4

130

1.6

130

1.8

160

2.0

160

2.3

200

2.6

200

2.9

230

3.2

230

3.5

250

3.8

250

4.0

250

Application: Overhead power lines, communication cables, hangers, suspensions, tethers and fixtures, etc.

20210705094338a44ff40c6f4e49fd8f77467b108cf9a3

20210705094338b75b4ba6e23a44c4a8d68d8eb15663d8

At present, the quality of our Export North America ACSR Overhead Wire Aluminum Area 240mm2 Steel Area 40mm2 ACSR Overhead Power Lines has reached the first class in the industry, the cost has reached the leading level in the industry, and the technical indicators have reached the advanced level. We abide by integrity as a basic principle of business activities, respect our agreements, contracts and value the fulfillment of promises made to our customers, investors and ourselves. Our company will continue to attach importance to product development and innovation to create greater value for customers at home and abroad.

Hot Tags: high strength galvanized steel strand, China high strength galvanized steel strand suppliers, manufacturers, factory, Color Coating Steel Sheets, PPGL coils, Concrete pipe pile tip, electrical concrete pole machine for power transmission, SS FITTINGS, Concrete Cone Electric Pole Manufacturing Equipment

Send Inquiry