Call Us: +8615989235884Email: zhangjianfeng13@jianhuaintl.com
enLanguage
Shenguan Fire Proof Mineral Cable Mineral Insulated Fire Resistant Cables Mining Power Cable Overhead Line Electric Aluminium Alloy

Shenguan Fire Proof Mineral Cable Mineral Insulated Fire Resistant Cables Mining Power Cable Overhead Line Electric Aluminium Alloy

Used for mechanical re-inforcement in the manufacture of aluminum conductor steel reinforced(ACSR) Cable & Conductor ACSR Core wire is used in reinforcement of aluminium conductors used in distribution and transmission of electricity.

During these years of development, we have witnessed the progress and improvement of China's pre painted galvalume steel coils, PPGI corrugated sheets, Overhead power lines. You can place an order and try it. If everything goes well, you can place a long-term order. We always adhere to the concept of sustainable development to lead the overall situation, in-depth practice of industrial transformation.

Product Introduction

High Strength Galvanized Steel Strand is a steel strand with national standard quality, high tensile strength and long service life. It can be used in the construction of agricultural greenhouses, power communications and transportation. It is convenient and fast, can be bent and laid according to the construction environment and terrain, and has high flexibility. It is suitable for a variety of scenarios, has a wide range of uses, and has strong applicability.

Features

High Strength Galvanized Steel Strand uses advanced galvanizing technology. It has great anti-corrosion, anti-rust and corrosion resistance. It has strong bearing capacity and good toughness . It has complete specifications for you to choose according to your needs. It is not easy to rust. It is a product with high quality, good functionality,  and please rest assured to use.

Wire Dia.: 1x7 4.2mm-12.0mm; 1x19 8.0mm-17.5mm

1) Application: Used for mechanical re-inforcement in the manufacture of aluminum conductor steel reinforced(ACSR) Cable & Conductor ACSR Core wire is used in reinforcement of aluminium conductors used in distribution and transmission of electricity. ACSR Core strand.

2) Material: high carbon steel, High strength Galvanized Steel Strand

3) Construction: 3-wire strand (1×3), 7-wire strand (1×7), 19-wire strand (1×19), 37-wire strand (1×37)

Strand sizes: 1.0mm — 18.92 mm

4) Tensile strength: different Grade from min.1470 N/mm² to min.1960N/mm²

20210705094301df6b24571dcb4d46aa844b2e483d3be6

20210705094308297035d0e1ef4d37b8af15ba4e03c7df

The size of Galvanized Steel Strand for ACSR as follows

m㎡ Nominal Cross-section area

Construction Number of Wires

m㎡ Calculated Cross-section area

mm Diameter

Kg/km

Weight per length

KN

Minimum breaking load of strand

20 Ω/km

20 centigrade DC Resistance

Wire Dia.

Strand Dia.

JG1A

JG2A

JG3A

JG4A

JG5A

10

7

10.8

1.40

4.20

84.8

14.44

15.62

17.46

20.15

21.12

17.9754

15

7

17.8

1.80

5.40

140.1

23.87

25.83

28.86

33.31

34.91

10.8740

20

7

22.0

2.00

6.00

173.0

29.47

31.89

35.63

41..12

43.10

8.8079

25

7

26.6

2.20

6.60

209.3

35.66

38.58

43.11

49.76

52.15

7.2793

35

7

37.2

2.60

7.80

292.4

48.69

52.40

59.09

67.64

70.99

5.2118

50

7

49.5

3.00

9.00

389.2

64.82

69.77

78.67

90.05

94.51

3.9146

55

7

56.3

3.20

9.60

442.9

72.62

79.38

87.26

99.65

105.3

3.4406

65

7

67.3

3.50

10.5

529.8

86.88

94.96

104.4

119.2

125.9

2.8761

80

7

79.4

3.80

11.4

624.5

102.4

109.6

120.7

136.5

144.5

2.4399

90

7

88.0

4.00

12.0

692.0

113.5

121.4

133.7

151.3

160.1

2.2020

m㎡ Nominal Cross-section area

Construction Number of Wires

m㎡ Calculated Cross-section area

mm Diameter

Kg/km Weight per length

KN Minimum breaking load of strand

Ω/km

20 centigrade DC Resistance

Wire Dia.

Strand Dia.

JG1A

JG2A

JG3A

JG4A

JG5A

40

19

38.2

1.60

8.00

301.9

51.19

55.39

61.89

71.44

74.88

5.0939

50

19

48.3

1.80

9.00

382.1

64.79

70.11

78.33

90.41

94.76

4.0248

60

19

59.7

2.00

10.0

471.7

79.98

86.55

96.70

111.6

117.0

3.2601

70

19

72.2

2.20

11. 0

570.8

96.78

104.73

117.00

135.1

141.6

2.6943

80

19

78.9

2.30

11.5

623.9

103.4

111.3

125.5

143.7

150.8

2.4651

95

19

94.8

2.52

12.6

748.9

124.14

133.62

150.68

172.5

181.0

2.0535

100

19

101

2.60

13.0

797.2

132.1

142.2

160.4

183.6

192.7

1.9291

125

19

125

2.90

14.5

991.8

164.4

177.0

199.5

228.4

239.7

1.5506

150

19

153

3.20

16.0

1207.6

197.1

215.5

236.9

270.5

285.7

1.2735

185

19

183

3.50

17.5

1444.7

235.8

257.8

283.3

323.6

341.8

1.0645

YB/T5004 According to YB/T5004

dmm Nominal wire dia.

Nominal tensile strength Mpa

L0=200mm Elongation in 200mm min, %

Twist(No./360°)(L0=100d) Nominal tensile strength/Mpa

1270

1370

1470

1570

1670


Not less than

1.40

1270

1370

1470

1570

1670

2.0

18

16

16

14

12

1.50

1.60

1.70

1.80

3.0

16

14

14

12

10

2.00

2.20

2.40

3.0

16

14

14

12

10

2.60

2.80

14

12

12

10

8

3.00

3.5

14

12

12

10

8

3.20

3.50

3.80

4.00

Dominal Dia And Breaking Load

Construction

mm Wire dia.

mm Nominal strand dia.

m㎡ Nominal Cross-section area

Nominal tensile strength Mpa

Weight kg per km

1270

1370

1470

1570

1670

Minimum breaking load of strand

1x7

1.40

4.20

10.78

12.60

13.59

14.58

15.57

16.56

85.60

1.60

4.80

14.07

16.44

17.73

19.03

20.32

21.62

112.00

1.80

5.40

17.81

20.81

22.45

24.09

25.72

27.36

141.00

2.00

6.00

21.99

25.69

27.72

29.74

31.76

33.79

175.00

2.20

6.60

26.61

31.10

33.55

36.00

38.45

40.88

210.00

2.60

7.80

37.17

43.43

46.85

50.27

53.69

57.11

295.00

3.00

9.00

49.50

57.86

62.42

66.98

71.54

76.05

411.90

3.20

9.60

56.30

65.78

70.96

76.14

81.32

86.50

447.00

3.50

10.50

67.35

78.69

84.89

91.08

97.28

103.48

535.00

3.80

11.40

79.39

92.76

100.10

107.40

114.70

121.97

630.00

4.00

12.00

87.96

102.8

110.90

119.00

127.00

135.14

698.00

1X19

1.60

8.00

38.20

43.66

47.10

50.54

53.98

57.41

304.00

1.80

9.00

48.35

55.26

59.62

63.97

68.32

72.67

385.00

2.00

10.00

59.69

68.23

73.60

78.97

84.34

89.71

475.00

2.20

11.00

72.20

82.58

89.00

95.58

102.09

108.52

569.00

2.30

11.50

78.94

90.23

97.33

104.40

111.50

118.65

628.00

2.60

13.00

100.90

115.30

124.40

133.50

142.60

151.65

803.00

2.90

14.50

125.50

143.40

154.70

166.00

177.30

188.63

999.00

3.20

16.00

152.80

174.70

188.40

202.20

215.90

229.66

1220.00

3.50

17.50

182.80

208.90

225.40

241.80

258.30

274.75

1460.00

4.00

20.00

238.80

272.90

294.40

315.90

337.40

358.92

1900.00

Zinc Coating Requirement

d mm Nominal wire dia.

Zinc-coated weight g/㎡

Class A

1.4

130

1.6

130

1.8

160

2.0

160

2.3

200

2.6

200

2.9

230

3.2

230

3.5

250

3.8

250

4.0

250

Application: Overhead power lines, communication cables, hangers, suspensions, tethers and fixtures, etc.

20210705094338a44ff40c6f4e49fd8f77467b108cf9a3

20210705094338b75b4ba6e23a44c4a8d68d8eb15663d8

In the face of future opportunities, we will invigorate our spirits, meet challenges, always put the interests of users first, continue to develop and update products to provide users with superior cost-effective Shenguan Fire Proof Mineral Cable Mineral Insulated Fire Resistant Cables Mining Power Cable Overhead Line Electric Aluminium Alloy. We are willing to work closely with our colleagues for mutual benefit and win-win, and work together to build a healthy, happy and rich life value. If you have the requirement for any of our goods, make sure you contact us now.

Hot Tags: high strength galvanized steel strand, China high strength galvanized steel strand suppliers, manufacturers, factory, Stainless Steel Pipe, High Strength Galvanized Steel Wire, Construction structural S235JR mild steel, Stainless Steel Fittings, PHC Prestressed Concrete Pipe Pile, End plate for prestressed pipe pile

Send Inquiry